RESULTS :

1. Reproducibility : Anova tests shows no statistical significant difference between the three reconstructions. Average and standard deviation values of the parameters describing the axes of rotation are described in Table 1.

 

2. Simulation of the clubfoot deformity movement on the normal foot :

STACK OF IMAGES

ANIMATION

3. Simulation of the motion of the clubfoot bones :

ANIMATION OF FRAMES

SIMULATION ON THE CLUBFOOT

4. Animation of the movement of the osseous nucleus and cartilage body :

CALCANEUS

Normal Foot / Clubfoot

TALUS

Normal Foot / Clubfoot